PvModules
Meters.EnergyProfiles{Pv}.PvSimulation.EnergySite.PvSystems.PvArrays.PvModules
An array containing specifications for the PV module or modules that make up a PV array.
Count
The number of units for the particular PV module
Possible Values: Any integer value.
Required.
NameplateDCRating_kW
The nameplate rating in kW-DC for the particular module.
Possible Values: Any decimal value.
Required.
PtcRating_kW
The PVUSA (Photovoltaics for Utility Systems Applications) Test Conditions rating in kW-DC for the particular module. The PTC rating of a module is typically about 90% of its nameplate rating, which is typically measured under Standard Test Conditions (STC).
Possible Values: Any decimal value.
Required.
PowerTemperatureCoefficient_PercentPerDegreeC
The percent by which the PV module power output will decrease from the PTC rating per degree Celcius of temperature variation from the cell reference temperature under testing conditions (assumed to be 45℃).
Possible Values: A decimal value between 0 and 100 inclusive.
Default: 0.4.
NominalOperatingCellTemperature_DegreesC
The temperature in degrees Celcius reached by the PV module when open circuited and placed under the following conditions:
- Irradiance on cell surface = 800 W/m2
- Air Temperature = 20°C
- Wind Velocity = 1 m/s
- Mounting = open back side
Possible Values: Any decimal value.
Default: 45.